Any Querries ? Call Us :- +91-9718899666
Home » Our Products » Heating » HYBRIDIZATION INCUBATOR

HYBRIDIZATION INCUBATOR
APPLICATIONS
Hybridization oven/incubator is ideal for sterile laboratory testing and where the integrity of the sample must be preserved while heating it to the exact temperature for the right period of time. These simple and versatile instruments are found in applications including nucleic acid hybridizations such as Northern (RNA) blots/hybridizations, Southern (DNA) blots/hybridizations, Western (Protein) blots, and molecular biology assays.

Used in life science laboratories to perform membrane hybridizations with a hybridization incubator. Hybridization incubators, also known as hybridization ovens, provide defined temperature control, agitation, and consistency throughout the incubator chamber.
SALIENT FEATURES & CONSTRUCTION
Temperature range from ambient (+5°C) to 90°C ± 0.5°C controlled by P.I.D. controller. Chamber made of S.S. 304 is provided with air circulation fan. Rotator is inbuilt and is provided with racks to hold six bottles (60 mm Dia × 200 mm Depth) at a variable speed of 2 to 16 rmp.
  • Hybridizer and UV crosslinker in one self-contained space-saving unit
  • Designed for effective, efficient crosslinking and hybridization at one location with each section can operate at the same time
  • Precise temperature control, ambient to 99.9°C and variable speed control at 10 to 18 rpm
  • Multiple bottle sizes fits up to ten with three different sized bottle configurations
The hybridization oven operates with microprocessor controls to monitor temperature and rotation speed of bottles for dynamic mixing capability. This is ideal for creating the optimum conditions needed for cDNA library screenings, primer synthesis and all nucleic acid hybridization. The UV crosslinker provides an extremely uniform shortwave radiation exposure chamber for bonding nucleic acid to medium, typically done prior to hybridization. UV output is measured by an internal sensor and controlled by an on-board microprocessor, enabling accurate, reliable and safe laboratory crosslinking. Preset or user-selected UV energy or UV time exposure are selected via touch pad.
What's include: bottle carousel, one large bottle 35 x 300mm.
  • Outer chamber is made of Mild Steel duly powder coated.
  • Inner chamber made of ALUMINIUM or STAINLESS STEEL (304) sheet.
  • Forced convection system ensures good mixing, strong dispersion and maintains higher temperature uniformity inside the chamber.
  • Door has double viewing window to observe the sample placed inside the chamber without disturbing the thermal condition.
  • Thermal loss is prevented by filling mineral wool (Insulation) in space between the outer body & Inner chamber.
  • Door Gasket fixed on the double walled door for proper sealing.
  • Fitted with heavy hinges with a ball catcher, spring loaded door closing device. Door is duly insulated.
  • Adjustable two ventilation slides control inner air / vapour circulation.
  • Beaded heating elements made of high quality Nichrome/Kanthal wire are placed in ribs, at bottom and sides for uniform heat distribution.
  • Inner chamber has ribs for placing the shelves at convenient levels. Supplied with 2 or 3 removable shelves.
  • Temperature is controlled by electronic digital temperature indicator cum controller from 50°C to100°C ± 1°C. fitted on the front panel for easy operations.
  • Different programme functions can be designed for a wide variety of applications, and even when used
  • Temperature is displayed by Digital LED with SV and PV display at front of the oven.
  • Front Panel is provided with ON/OFF switch, temperature controller and indicators.
  • Supplied with cord and plug.
  • Operating Voltage: 220 Volts AC (50 Hz).

TECHNICAL SPECIFICATIONS & ORDERING INFORMATIONS

Model No. INE 1 INE 2 INE 3 INE 4
Inner Chamber in MM (W x H x D) 300x300x300 355x355x355 455x455x455 455x605x455
Inches Conversion 12 x 12 x 12 14 x 14 x 14 18 x 18 x 18 18 x 24x 18
Capacity 28 ltrs 43 ltrs 90 ltrs 105 ltrs
Heating Load 0.50 KW 0.50 KW 1.00 KW 1.00 KW
No. of Shelves 2 2 2 2
Temperature Range 5°C above ambient to 70°C
Temp. Controller By Microprocessor Based PID Digital Temperature Indicator cum Controller.
Temp. Sensitivity +1°C.
Air Circulation By forced convection system
Relay Solid state electronic relay with protective heat sink.
Auto Tuning System System is compatible with auto tuning system

Model No. INE 5 INE 6 INE 7 INE 8
Inner Chamber in MM (W x H x D) 455 x 605 x 605 605x605x605 605x910x455 605x910x605
Inches Conversion 18 x 24 x 24 24 x 24 x 24 24 x 36 x 18 24 x 36 x 24
Capacity 120 ltr 215 ltrs 240 ltrs 325 ltrs
Heating Load 1.50 KW 1. 50 KW 1.50 KW 2.00 KW
No. of Shelves 2 2 3 3
Temperature Range 5°C above ambient to 70°C
Temp. Controller By Microprocessor Based PID Digital Temperature Indicator cum Controller.
Temp. Sensitivity +1°C.
Air Circulation By forced convection system
Relay Solid state electronic relay with protective heat sink.
Auto Tuning System System is compatible with auto tuning system

OPTIONAL FEATURES

Controlling of Temperature By Profile (Micro Programmable Controller)
Audio Alarm System Activates at end of cycle Buzzer.
Timer Facility Can be in built with Digital Electronic Timer
Communication Port RS - 485 with Window based software
PLC Based Control Systems With Touch Screen Display with Direct Thermal / Dot Matrix Printer.
LCD Controller with Data Logger 16 x 2) with optional RS-485 communication ports, cables, window based software with inbuilt data recording.